MYTHEN2 for Laboratories

These versatile X-ray detectors with a 50-µm strip offer high quantum efficiency for the widest X-ray energy range: from titanium (Ti) to silver (Ag).

Request a quote

MYTHEN2 for Laboratories

DECTRIS® MYTHEN2 strip detectors bring synchrotron-like detection to the lab for all X-ray diffraction, scattering, and spectroscopy techniques. Their radiation hardness and maintenance-free operation make these detectors the perfect choice for academic research, multi-purpose service laboratories, portable diffractometers, and industrial sites that employ Good Manufacturing Practice (GMP) and Good Laboratory Practice (GLP) rules.

MYTHEN2 R offers the narrowest strip width (50 μm) on the market, providing unprecedented signal resolution. Single-photon counting eliminates dark current and readout noise while delivering superior data. MYTHEN2 R detectors also combine noise-free performance with high quantum efficiency for the widest X-ray energy range: from Ti to Ag. This unique combination of features will help you make the most of weak laboratory sources by maximizing the signal-to-noise ratio and minimizing measurement and data processing times.

  • ✓ Fast & accurate: these detectors offer noise-free detection at the highest commercially available count rate for an extended energy range (from 4 to 40 keV).
  • ✓ Modular & compatible: individual modules are easy to combine to build larger systems. The detectors also offer optional vacuum capability.
  • ✓ Reliable: detector performance will be maintenance- and service-free. Delivery terms are guaranteed, thanks to streamlined industrial production and top-notch support.

Detectors

MYTHEN2 R 1K

MYTHEN2 R 1K

This multipurpose device with unsurpassed resolution will meet the requirements of all X-ray diffraction, scattering, and spectroscopy techniques.

MYTHEN2 R 1D

MYTHEN2 R 1D

This detector is the perfect choice for portable diffractometers, stress measurements, and XRD benchtop systems.

Publications

Detector Specifications*

MYTHEN2 R 1K

MYTHEN2 R 1D

Strip width
[µm]

50

50

Strip height
[mm]

8

8 (450 μm only)
4 (320 μm only)

Active area (W x H)
[mm²]

64 x 8

32 x 8 (450)
32 x 4 (320)

Energy range (depending on the sensor thickness)
[keV]

5 - 40 (320)
6.6 - 40 (450)
7.4 - 40 (1,000)

4 - 40 (320)
6.6 - 40 (450)

Threshold range (depending on the sensor thickness)
[keV]

4.5 - 20 (320)
5.5 - 20 (450)
6.0 - 20 (1,000)

3.5 - 20 (320)
5 - 20 (450)

Frame rate (max.)
[Hz]

100

100

Count rate (max.)
[ph/s/strip]

106

106

Readout time
[µs]

89

89

Strips per module
[strips]

1,280

640

Sensor material

Silicon (Si)

Silicon (Si)

Sensor thickness
[µm]

320, 450, or 1,000

320 or 450

Point-spread function
[strips]

1

1

Vacuum compatibility

Optional

Optional

Module dimensions (W x H x D)
[mm³]

70 x 62 x 22

36 x 62 x 22

Cooling method

Air

Air

*All specifications are subject to change without notice.

Key Contact

Marcus Müller

Marcus Müller

Product Manager - Laboratories, XRD

marcus.mueller@dectris.com

Contact Marcus

Techniques

X-ray diffraction

X-ray diffraction

Patterns with both weak and intense reflections are no challenge for the high dynamic range of DECTRIS strip detectors.

Read more →
Spectroscopy

Spectroscopy

The combination of single-photon sensitivity with zero background noise enhances even the most advanced spectroscopic techniques.

Read more →
Residual stress

Residual stress

High-quality accurate data acquired in a metter of seconds, even with weal sources. DECTRIS 1D detectors fit any diffractometer geometry for portable to metrology instruments.

Read more →

Related News

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.

Request a quote

To get more information for a tender or learn more about purchasing a DECTRIS MYTHEN2® X-ray detector for synchrotron beamlines, reach out to us

Want to know more?

We are happy to answer any questions about us, our detectors, or the process of integrating our detectors into your experimental setup.

Contact us

Need support?

Our Support team is here to answer your questions and help you take full advantage of your detector.

Support request