JUNGFRAU

High Speed - High Flux - High Confidence: The DECTRIS JUNGFRAU® is the first charge-integrating detector from DECTRIS, built for the extreme flux of 4th-generation synchrotrons. Its per-pixel charge integration with three-level dynamic gain switching captures single photons and the most intense Bragg peaks in the same frame, without saturation, at a continuous 2,000 frames per second across the full 4-megapixel active area.

Request a QuoteWatch the Launch

The DECTRIS JUNGFRAU® is our first charge-integrating detector, built for the extreme flux of 4th-generation synchrotrons. Per-pixel charge integration with three-level dynamic gain switching captures single photons and the most intense Bragg peaks in the same frame, without saturation, at a continuous 2,000 frames per second across the full 4-megapixel area.

Each 75 µm pixel selects one of three calibrated gain stages depending upon the charge it collects: single-photon sensitivity at low flux; more than 10⁴ photons per pixel per frame at the top end. Charge integration has no instantaneous count-rate limit to plan around, and the sustained 2,000 Hz readout reliably records every frame of your experiment for seconds, minutes, or even hours. On-detector autosummation combines sub-frames on the fly, extending effective dynamic range and delivering fully calibrated images at the frame rate you need.

This detector is specifically built for applications that demand highest local intensities, such as  serial synchrotron crystallography (SSX); high-flux MX at kilohertz frame rates; pump-probe experiments; time-resolved SAXS/WAXS: Full-frame speed; uncompromised dynamic range; DECTRIS reliability.

  • ✓  Full-speed, full-frame: Continuous 2,000 fps across the full 4 MP frame - for every frame of the measurement, not just a fixed burst.
  • ✓  High dynamic range for the highest flux: From single photons to over 10⁴ photons per pixel per frame with no instantaneous count-rate limit: A powerful complement to photon counting.
  • ✓  Photon counts, out of the box: Energy calibration, pedestal correction, flat-field, and autosummation turn raw signal into photon counts for you:- no offline processing is required.
  • ✓  Easy to integrate, reliable: JUNGFRAU uses the same SIMPLON API, HDF5/NeXus, and Streaming interfaces as EIGER2 and PILATUS4; delivered and supported to DECTRIS standards.

Testimonial

„The DECTRIS JUNGFRAU is fully suitable for any application in crystallography, out of the box. We collected precise and accurate rotation MX data.”

- Gleb Bourenkov, EMBL Hamburg

Detector Specifications*

JUNGFRAU


Active area (W x H) [mm²]

155.1 × 162.6 mm²


Pixel array (W x H)

2068 × 2168 pixels


Pixel size (W x H) [µm²]

75 × 75 µm²


Count rate (max.) [ph/s/pixel]

2x2 binned: 1.8 x 108 Full: 4.5 x 107


Energy range [keV]

7 - 18 keV**


Threshold range [keV]

4.6 - 25


Frame rate (max.) [Hz]

2,000 Hz, continuous, full frame


Readout time

Continuous readout, duty cycle > 98%


Image bit depth [bits]

32 / 16 bit


Sensor thickness [µm]

450 µm


Inter-module gap (Hor./Vert.) [pixels]

12 / 40 pixels


Dimensions (W x H x D) [mm³]

300 × 313 x 551 mm


Weight [kg]

Approx. 30 kg


Number of detector modules (W x H)

8 (2 × 4 matrix)


*All specifications are subject to change without notice.

Key Contacts

Hans Gildenast

Application Scientist X-ray

hans.gildenast@dectris.com

Contact HANS
Sascha Grimm

Sascha Grimm

Product Manager - Synchrotrons

sascha.grimm@dectris.com

Contact Sascha

Related Documents

Related News

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.

Request a quote

To get more information for a tender or learn more about purchasing a DECTRIS SELUN® X-ray detector for synchrotron beamlines, reach out to us

Want to know more?

We are happy to answer any questions about us, our detectors, or the process of integrating our detectors into your experimental setup.

Contact us

Need support?

Our Support team is here to answer your questions and help you take full advantage of your detector.

Support request